gas-manufacturers
Manufacturers
GAS CHROMATOGRAPH
- Serving to more than 300 customers in South India.
- Repairs / Servicing to various manufacturers.
- Revived more than 700 instruments which were discontinued by the manufacturers.
Agilent
- 6820
- 6890
- 7820
- 7890


Perkin Elmer
- Clarus 480
- Clarus 500
- Clarus 580
- Clarus 600
- Clarus 680
- Auto system XL


Thermo
- GC 1000
- Trace Ultra
- Trace 1110
- Trace 600
- Trace 700
- CERES 800


Hewlett Packard
- HP 5890 Series II
- HP 6820
- HP 6890


Shimadzu
- GC 8A
- GC 9A
- GC 14B
- GC 2010
- GC 2014


Varian
- CP3400
- CP3800
- CP450
- CP450


Services to Other Manufacturers







Agilent
- 6820
- 6890
- 7820
- 7890


Perkin Elmer
- Clarus 480
- Clarus 500
- Clarus 580
- Clarus 600
- Clarus 680
- Auto system XL


Thermo
- GC 1000
- Trace Ultra
- Trace 1110
- Trace 600
- Trace 700
- CERES 800


Hewlett Packard
- HP 5890 Series II
- HP 6820
- HP 6890


Shimadzu
- GC 8A
- GC 9A
- GC 14B
- GC 2010
- GC 2014


Varian
- CP3400
- CP3800
- CP450
- CP450


Services to Other Manufacturers







Chromatography Faults, Read From the Chromatogram
On the GC side: retention times drifting between runs point at a gas leak, an ageing septum or liner, or flow-controller drift. An FID that will not ignite or a baseline full of spikes is a detector or gas-purity story. Ghost peaks trace back to the inlet. We service Agilent 6890, 7890 and 8890, Thermo TRACE 1110/1300 and GC Ultra, Shimadzu and Chemito systems — leak-testing the whole gas path and proving the repair with a standard test mix whose chromatograms ship with the service report.
On the HPLC side: pump pressure that fluctuates or will not build is check valves or plunger seals; a noisy UV baseline is a D2 lamp or flow cell; injection-volume scatter is the autosampler needle seal. Shimadzu LC-20AD, Prominence, LC-2010 and i-Series, Waters and PerkinElmer stacks are overhauled with genuine-spec wear parts we keep in stock, so routine repairs are not held up waiting.
Pharma and testing labs from Chennai to Delhi keep these systems under our preventive-maintenance AMC — septa, liners, seals and check valves replaced on schedule, priority breakdown response, software connection issues included. Downtime on a release-testing instrument costs more than a year of AMC.
Email a chromatogram or pressure trace if you have one — it usually tells us the fault before the call. Call +91 95000 10101, WhatsApp +91 95000 62555 or send the enquiry form — we reply the same working day.
What Customers Say About Our GC / HPLC Services
- ★★★★★✓
Very good Service for the instruments like AAS, UV and GC. Respond the customer complaints and solve the issues immediately.
- ★★★★★✓
I would like to sincerely thank the InstrumentCare service team for their prompt support and excellent service. Whenever we face any issue with our laboratory instruments such as UV, GC, or other analytical instruments, we immediately contact your service team. You respond quickly, arrange a service visit, identify the problem, and resolve it effectively. Your technical support, timely response, and professional approach help us maintain our instruments properly and minimize interruptions to our laboratory analysis. We highly appreciate your cooperation and continuous support. Thank you, InstrumentCare team, for your excellent service and valuable technical support.
Rated 4.9 from 127 Google reviews · Get your free quote →